UPSSTATS.HTML(5)
================

NAME
----

upsstats.html - HTML template for web-based Network UPS Tools upsstats

DESCRIPTION
-----------

This file is used by linkman:upsstats.cgi[8] to generate status pages.
Certain commands are recognized, and will be replaced with various
status elements on the fly.

FORMATTING
----------

Commands can be placed anywhere on a line, but must start and end with `@`.

Any extra characters before or after the commands will be passed through
unchanged.

It is allowed to use more than one command on a single line, as long as
each command has its own start and end character.

If you need to use the `@` sign, use HTML entity ++\&#64;++ to prevent it
from being treated as a start character.

BLOCK CONTROL
-------------

Some commands begin blocks -- sections of the template that will be
included, excluded, or repeated depending on certain parameters.

BLOCK CONTROL - ITERATION
~~~~~~~~~~~~~~~~~~~~~~~~~

*@FOREACHUPS@*::
Starts a block that will be repeated for each MONITOR directive in the
linkman:hosts.conf[5].  This is how you can generate pages that monitor
all of your systems simultaneously.

*@ENDFOR@*::
Ends a FOREACHUPS block.

BLOCK CONTROL - MATCHING SPECIFIC CASES
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

*@IFSUPP 'var'*@*::
Starts a block that will only be printed if the variable var is
supported by the current UPS.  This is generally used to suppress "not
supported" messages by avoiding the label and variable call entirely.

*@IFEQ* 'var' 'value'*@*::
Starts a block if the value returned from the variable 'var' matches
'value'.

*@IFBETWEEN* 'varlow' 'varhigh' 'varvalue'*@*::
Starts a block if the value returned by the variable 'varvalue' is between
the values returned by the variables 'varlow' and 'varhigh'.

*@ELSE@*::
If the previous IF-command did not match, perform this instead.

*@ENDIF@*::
Ends an IF/ELSE-block.

BLOCK CONTROL - ADVANCED EXPRESSIONS
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Even though the parser is pretty limited, it's still possible to create
rather advanced expressions. The key to this is the fact that
multiple block control commands are AND:ed. This is illustrated with an
example (more examples are available in upsstats.html).

   @IFSUPP ambient.humidity@
   @IFSUPP ambient.temperature@
   This UPS knows both ambient temperature and humidity.
   @ELSE@
   @IFSUPP ambient.humidity@
   This UPS only knows ambient humidity.
   @ELSE@
   @IFSUPP ambient.temperature@
   This UPS only knows ambient temperature.
   @ELSE@
   This UPS knows nothing, how annoying.
   @ENDIF@

OTHER COMMANDS
--------------

*@AMBTEMP@*::
Insert the ambient temperature in the current temperature scale.

*@DATE* 'format'*@*::
Insert the current date and time.  The format string is passed to `strftime`,
so almost anything is possible.  See linkmanext:strftime[3] for possible values.

*@DEGREES@*::
Insert the entity for degrees (&deg;) and either C or F depending on
the current temperature scale.

*@HOST@*::
Insert the designation of the host being monitored, like `myups@localhost`.

*@HOSTDESC@*::
Insert the host's description from linkman:hosts.conf[5].

*@HOSTLINK@*::
Insert a link to upsstats.cgi with the "host" variable set to the
current UPS.  This is only useful within a FOREACHUPS block.

*@IMG* 'varname' ['extra']*@*::
Insert an IMG SRC to linkman:upsimage.cgi[8] for one of these
status variables:

	battery.charge;; Battery charge -- a percentage

	battery.voltage;; The charge on the battery in volts

	input.frequency;; Incoming utility frequency (Hz)

	input.voltage;; Incoming utility voltage

	input.L1-L2.voltage;; Incoming voltage, L1-L2 (3phase)

	input.L2-L3.voltage;; Incoming voltage, L2-L3 (3phase)

	input.L3-L1.voltage;; Incoming voltage, L3-L1 (3phase)

	output.frequency;; Outgoing utility frequency (Hz)

	output.voltage;; Outgoing voltage (from the UPS)

	output.L1-L2.voltage;; Outgoing voltage, L1-L2 (3phase)

	output.L2-L3.voltage;; Outgoing voltage, L2-L3 (3phase)

	output.L3-L1.voltage;; Outgoing voltage, L3-L1 (3phase)

	output.L1.power.percent;; UPS load, L1 (3phase)

	output.L2.power.percent;; UPS load, L2 (3phase)

	output.L3.power.percent;; UPS load, L3 (3phase)

	ups.load;; UPS load -- percentage

	ups.temperature;; UPS temperature

'extra' is where you can put additional definitions.  Right now
the valid definitions are colors for various parts of the bars drawn
by linkman:upsimage.cgi[8].  Possible color names are:

	back_col;; background color

	scale_num_col;; scale number color

	summary_col;; summary color (number at the bottom)

	ok_zone_maj_col;; major scale color for the normal ("ok") zone

	ok_zone_min_col;; minor scale color for the normal ("ok") zone

	neutral_zone_maj_col;; major scale color for the neutral zone

	neutral_zone_min_col;; minor scale color for the neutral zone

	warn_zone_maj_col;; major scale color for the warning zone

	warn_zone_min_col;; minor scale color for the warning zone

	bar_col;; the color of the bar in the middle

All colors are hex triplets -- e.g. `0xff0000` is red, `0x00ff00` is green,
and `0x0000ff` is blue.

Examples:

	@IMG battery.charge@
	@IMG battery.charge back_col=0xff00ff bar_col=0xaabbcc@
	@IMG input.voltage ok_zone_maj_col=0x123456@

*@REFRESH@*::
Insert the META header magic for refreshing the page if that variable
has been set by the browser.  This needs to be in the HEAD section of
the page.

*@STATUS@*::
Expand the abbreviations in the ups.status variable -- OL becomes
"On line", OB becomes "On battery", and so on.

*@STATUSCOLOR@*::
Insert red, green, or yellow color triplets depending on the severity of
the current UPS status.  Normal operations are green, warnings like
voltage trim/boost or "off" are yellow, and other events like being on
battery or having a low battery are red.

*@VAR* 'varname'*@*::
Insert the current value of the status variable varname on the host being
monitored, or "Not supported".

*@RUNTIME@*::
Inserts the current runtime, in `hh:mm:ss` format.

*@TEMPC@*::
Use the Celsius scale for temperature data (default).

*@TEMPF@*::
Use the Fahrenheit scale for temperature data.

*@UPSTEMP@*::
Insert the UPS temperature in the current scale.

*@BATTTEMP@*::
Insert the battery temperature in the current scale.

*@UTILITYCOLOR@*::
Obsoleted. Use IFBETWEEN instead (see example in upsstats.html).

*@VERSION@*::
Insert the version number of the software.

OTHER TEMPLATES
---------------

linkman:upsstats.cgi[8] will also open a file called `upsstats-single.html`
if you call it with `host=` set in the query URL.  That file uses the same
rules and techniques as documented here.

SEE ALSO
--------

linkman:upsstats.cgi[8], linkman:upsimage.cgi[8]

Internet resources:
~~~~~~~~~~~~~~~~~~~

The NUT (Network UPS Tools) home page: https://www.networkupstools.org/